DC/DC Converter
TEN 40WIE Series, 40 Watt
•
Developed to maximize quality in a cost
efficient design
•
•
•
Excellent temperature capabilities
•
Minimal heat development due to high
efficiencies up to 93%
2” x 1” metal package (6-side shielded)
Wide 4:1 input voltage range:
9-36, 18-75 VDC
•
Operating temperature range -40 to
+85°C
•
•
•
1600 VDC I/O-isolation
•
3-year product warranty
Remote On/Off and Trim function
Protection against short circuit,
overvoltage and overtemperature
UL 62368-1 IEC 62368-1
The TEN 40WIE is rounding out Traco Power’s existing 40 Watt product range.
Driven by current market trends this series was developed to maximize quality
and cost efficiency in one product. Due to a new design approach the TEN
40WIE thus offers a cost efficient solution with not only no concession on quality or reliability but even improved specifications compared to its predecessor. It
comes in a standard 2” x 1” metal package with a 4:1 input voltage range. High
efficiencies of up to 93% allow for an operating temperature range (natural
convection) of -40 to +70°C without power derating (model dependent). Certified according to the latest IT standard (IEC/EN/UL 62368-1) and equipped
with additional features like remote on/off function and protection against short
circuit, overvoltage and over temperature the TEN 40WIE series is suitable for
many industrial applications.
Models
Order Code
Input Voltage
Range
TEN 40-2410WIE
TEN 40-2411WIE
TEN 40-2412WIE
TEN 40-2413WIE
TEN 40-2415WIE
TEN 40-2422WIE
TEN 40-2423WIE
TEN 40-2425WIE
TEN 40-4810WIE
TEN 40-4811WIE
TEN 40-4812WIE
TEN 40-4813WIE
TEN 40-4815WIE
TEN 40-4822WIE
TEN 40-4823WIE
TEN 40-4825WIE
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
+24 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
+24 VDC
12'200 mA
8'000 mA
3'333 mA
2'666 mA
1'666 mA
1'666 mA
1'333 mA
833 mA
12'200 mA
8'000 mA
3'333 mA
2'666 mA
1'666 mA
1'666 mA
1'333 mA
833 mA
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
–24 VDC
1'666 mA
1'333 mA
833 mA
–12 VDC
–15 VDC
–24 VDC
1'666 mA
1'333 mA
833 mA
typ.
90 %
92 %
92 %
93 %
91 %
91 %
91 %
91 %
90 %
91 %
92 %
92 %
92 %
91 %
91 %
92 %
Options
TEN-HS1
- Optional Heat Sink with Height = 0.22 inch: www.tracopower.com/products/ten-hs1.pdf
TEN-HS8
- Optional Heat Sink with Height = 0.3 inch: www.tracopower.com/products/ten-hs8.pdf
- Optional Heat Sink with Height = 0.8 inch: www.tracopower.com/products/ten-hs10.pdf
on demand
- Optional Heat Sink with Height = 0.5 inch: www.tracopower.com/products/ten-hs9.pdf
(backorder with MOQ
non stocking item) - Optional models with pre-assembled heatsink
- Optional models with inverse Remote On/Off function (passive = off)
www.tracopower.com
September 20, 2023
Page 1 / 5
TEN 40WIE Series, 40 Watt
Input Specifications
Input Current
- At no load
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
15 mA typ.
10 mA typ.
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
7 VDC min. / 8 VDC typ. / 8.8 VDC max.
15 VDC min. / 16 VDC typ. / 17.5 VDC max.
8'000 mA (fast acting)
4'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
Capacitive Load
- single output
- dual output
single output models:
dual output models:
single output models:
dual output models:
dual output models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
24 / -24 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
24 / -24 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
–10% to +20% (15 & 24 Vout models)
±10% (other models)
(single output models only)
(By external trim resistor)
www.tracopower.com/overview/ten40wie
Output power must not exceed rated power!
±1% max.
0.2% max.
0.2% max.
0.3% max.
0.5% max. (Output 1)
0.5% max. (Output 2)
5% max.
75 mVp-p typ.
75 mVp-p typ.
100 mVp-p typ.
100 mVp-p typ.
150 mVp-p typ.
100 / 100 mVp-p typ.
100 / 100 mVp-p typ.
150 / 150 mVp-p typ.
22'000 µF max.
12'000 µF max.
2'000 µF max.
1'300 µF max.
490 µF max.
980 / 980 µF max.
630 / 630 µF max.
250 / 250 µF max.
Not required
±0.02 %/K max.
30 ms typ. / 60 ms max.
Continuous, Automatic recovery
150% typ. of Iout max.
125% typ. of Vout nom.
(By Zener diode)
250 µs typ. (25% Load Step)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
TEN 40WIE Series, 40 Watt
Safety Specifications
Safety Standards
EN 62368-1
IEC 62368-1
UL 62368-1
www.tracopower.com/overview/ten40wie
PD 2
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EMS Immunity
External filter proposal:
Air:
Contact:
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/ten40wie
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
2 x KY 220 µF || SMDJ36A (12 Vin models)
2 x KY 220 µF || SMDJ58A (24 Vin models)
2 x KY 220 µF || SMDJ120A (48 Vin models)
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Over Temperature
Protection Switch Off
Cooling System
Remote Control
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–55°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten40wie
115°C typ. (Automatic recovery)
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Protection Mode
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
Natural convection (20 LFM)
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
3 mA typ.
-0.5 to 1.0 mA
(Optional models with inverse Remote On/Off
function (passive = off))
2'000 m max.
225 - 275 kHz (PWM)
250 kHz typ. (PWM)
Functional Insulation
1'600 VDC
1'600 VDC
1'600 VDC
1'000 MΩ min.
1'500 pF max.
1'245'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
TEN 40WIE Series, 40 Watt
Environment
- Vibration
- Mechanical Shock
- Thermal Shock
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
Copper
Non-conductive FR4 (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Lead-Free Wave Soldering
260°C / 6 s max.
34 g
- Case to Ambient
10.8 K/W typ. (without heatsink)
10.3 W/K typ. (with heatsink TEN-HS1)
9.3 W/K typ. (with heatsink TEN-HS8)
7.7 W/K typ. (with heatsink TEN-HS9)
6.2 W/K typ. (with heatsink TEN-HS10)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
066cb3a2-f918-4ca5-9d61-45dba6944ab5
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten40wie
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
TEN 40WIE Series, 40 Watt
Outline Dimensions
(0.1)
Pinout
3
25.4 (1.0)
5
(0.8)
Bottom View
(0.4)
2
20.32
4
1
10.16
6
45.72 (1.8)
Dimensions in mm (inch)
Tolerances: x.x ±0.5 (±0.02)
x.xx ±0.25 (±0.01)
Pin dimension tolerance ±0.1 (±0.004)
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
–Vin (GND)
–Vin (GND)
2
3
Remote On/Off Remote On/Off
4
+Vout
+Vout
5
–Vout
Common
6
Trim
–Vout
10.2
(0.4)
(0.22)
2.5 (0.1)
5.6
(0.3)
7.62
17.78 (0.7)
2.54
(2.0)
(0.1)
2.54
50.8
Ø1.0 (Ø0.04)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 5 / 5